• Original 3044196 Speed Control Unit Controller
  • Original 3044196 Speed Control Unit Controller
  • Original 3044196 Speed Control Unit Controller
  • Original 3044196 Speed Control Unit Controller

Original 3044196 Speed Control Unit Controller

Conditions
of Use:
Land Use
Usage: Common Units
Output Type: AC Three Phase
Cooling
Method:
Water Cooling
Installation
Method:
Portable
Generator
Type:
Diesel Generator
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
3044196
Delivery Time
2days
Warranty
One Year
G.W
0.5kg
Model
3044196
Transport Package
Strong Carton
Specification
original
Trademark
SINOSTAR
Origin
China
HS Code
8501109190
Production Capacity
100sets/Month

Product Description




Original 3044196 Speed control unit controller

Application Features: 

1. Low smoke displacement, soft noise 

   Meet the demand of environment protection imp rive people' s feeling. 

2. Easily start in cold, plateau and Ww pressure areas, 

     Especially for N-G-250kw and K-G-300kw sets. 

3. High ability to anti-disturbance Stable operation due to the large power walkie-talkie· 

4. Actuator can not be damaged in case of short circuit due to the output protector. 

5. Diesel with water pump cam start with wad, the range of round per minute cam be ± 600, that is 1000-1200 rpm. 

Principles:

The oil valve of the speed regulator is totally open and if the supercharger low-speed and with little 
air input, So it is difficult to ignite the fuel and cannot completely ignite and have thick smoke displacement. It starry 400-1200 rpm, It need 3-5or 10-20 minute to accelerate. 
It can easily start if we decrease the oil input. After it start, then increase' The oil input, the speed and the diesel generator temperature will increase gradually. Thus, the smoke displacement is ww and the noise is soft. The operation of and use of the set after start is same as other regulators. 

Operation methods:

1. Apearance Feature: It is same as other regulators. 

2. Switchesc: Seitches for after start while all the 3 switches downside, it can ccelerate immediately, while switch them upside respectively. It can accelerate in 5' , 10' , 15respectively. As the picture described (7-10 cannot connect prompt switches). The time more needs the smoke thinner and much easier to start. 

3. The lasting time of the start switch vibration is a little wag. During acceleration, if there is displacement stroke and displace black smoke, please regulate GAIN. 

4. If the sets adopt self-start 

Specification
3044196
 Input  Supply  24 VDC ±20%
 Polarity  Negative Ground (Case Isolated)
 Power Consumption  40 MA 
 Maximum Actuator Current  4.5 A continuous
 Speed Sensor Signal  2-120 Volts RMS
 Performance  Isochronous Operation/Steady State Stability  ±0.25% or better
 Speed Range/Governor  1K to 6.5K Hz continuous
 Speed Drift with Temperature  ±1 Max
 Idle Regulation  260±20 Hz
 Droop Adj. Max.   400 Hz., ±75Hz. Per 1.0A change
 Speed Trim Range  ±200 Hz with 1 ohm connected
 Remote Variable Speed Range  25 to 100% of rated speed
 Impedance  1m ohms
 Environmental  Ambient Operating Temperature Range  -40 to +85 Deg. C
 Relative Humidity  Up to 95%
 All Surface Finishes  Fungus Proof and Corrosion Resitant
 Reliability  Vibration  20 to 100 Hz. 500mm/sec

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Trading Company
Year of Establishment
2015-03-24
Plant Area