Technical Specifications :
1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade nickel-chromium alloys resistive wire covered by 3-year warranty.
2. Rated testing voltage: AC 3P4W, 110-480 VAC 50/60HZ.
3. Cooling mode: forced air-cooled, fans mounted on the side of the load bank blow horizontally. External utility power or internal tested power supply for fans.
4. Working mode: load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw.
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
SCHNEIDER contactors.
SIEMENS switches, knobs and indicators.
ABB circuit breakers.
OMRON intermediate relays.
PHOENIX terminal blocks.
6. Parameter measuring accuracy grade: 0.5.
7. Load control accuracy: ±3%.
8. Load bank protections: over heating protection, cooling fans failure protection and over load protection with alarm.
9. Control mode: two control modes available: a) Local manual control; b) Optional: Manual control via a remote control panel (max control distance is 20m).
10. Parameter display and measurement: Control panel contains a Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: a professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing).
11. Operating environment: Altitude: ≤1000m above sea level. Ambient temp: -10ºC~+40ºC Relative humidity: ≤80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.
Product specifications:
GENERATOR TESTER SPECIFICATIONS | ||||
Measurement | Range | Accuracy | Resolution | Overload |
Voltage (V) | 10.0~500.0V | ± (0.4% reading+0.1%range) | 0.1V | 600V |
Current (A) | 0.030~5.000A | ± (0.4% reading+0.1%range) | 0.001A | 6A |
Power | According to volt range | Power factor =1.0 | <200W 0.1W | |
& current range | ± (0.4% reading+0.1% range) | ≥200W 1W | ||
Power factor =0.5 | ≥2kW 10W | |||
± (0.8% reading+0.2% range) | ||||
Power Factor | 0.20~1.00 | ±0.02 | 0.001 | |
Frequency | 45~65Hz | ±0.2Hz | 0.01Hz | |
Running Time | 99h59m | ±2min/hour | 1 minute | |
Energy | 99999kWh | Power factor= 1.0 | 0.001kwh | |
(kWh) | ± (0.4% reading+0.1% range) | |||
Power factor=0.5 | ||||
± (0.8% reading+0.2% range) | ||||
Harmonic Analysis | 2-50 times | |||
(%) | and total harmonic |
Model | Testing | Type | Duty | Cooling | Phase | Rated | Rated | Dimensions | Weight |
capacity | of | system | Testing | Frequency | (L*W*H) | (kg) | |||
load | Voltage | (mm) | |||||||
SPLB-100 | 0 - 100 kw | Resistive | Continuous | Industrial | Available | 110-480 | 50/60 Hz | 960*1060*1400 | 350 |
SPLB-200 | 0 - 200 kw | or | grade | at both | VAC | 1560*1310*1650 | 837 | ||
SPLB-300 | 0 - 300 kw | Reactive, | axial fan | single | 1690*1440*1750 | 1083 | |||
SPLB-400 | 0 - 400 kw | PF = | and | 1900*1600*1900 | 1200 | ||||
SPLB-500 | 0 - 500 kw | 1.0 or 0.8 | three | 1900*1600*1900 | 1400 | ||||
SPLB-600 | 0 - 600 kw | phase | 2100*1730*2000 | 1550 | |||||
SPLB-700 | 0 - 700 kw | 2100*1730*2000 | 1650 | ||||||
SPLB-800 | 0 - 800 kw | 2400*2330*2100 | 1750 | ||||||
SPLB-1000 | 0 - 1000 kw | 2400*2330*2200 | 2150 | ||||||
SPLB-2000 | 0 - 2000 kw | 20 ft container | 6000 | ||||||
SPLB-5000 | 0 - 5000 kw | 40HC container | 16000 |